Carbon Fiber Thermal Pad for Thin Devices
How a carbon fiber thermal pad behaves in a thin device: installed thickness against clip force, real contact pressure, non-insulating risk and optics.

A wearable, a camera module, a phone that is 9 mm thick with the display bonded on: in all three the chip often sits 0.35 to 0.55 mm below the metal that has to carry its heat, and the clip, frame or screw boss that closes the stack contributes a few newtons at most. Choosing a carbon fiber thermal pad for thin devices starts from those two numbers, not from the conductivity printed on the box. The same pad that is the right answer in a server lid can be the wrong answer here, and the reason is usually not the material.
This guide works through the constraints in the order they bind: the height budget, the pressure the assembly can actually apply, the potentials on either face, and the direction the heat has to travel. Two of the usual selling points — light weight and "no silicone" — do not survive contact with the arithmetic, and the sections on mass and on silicone show why.
What a Carbon Fiber Thermal Pad for Thin Devices Really Is
A carbon fiber thermal pad is a compressible sheet whose conductive phase — the part that actually carries heat — is carbon fiber standing across the thickness rather than lying flat in it. It is a thermal interface material (TIM) like any other, and a carbon fiber thermal interface material differs from a silicone gap pad in one respect that drives everything else: the conduction path is the fiber, not the polymer. Carbon fiber moves heat far better along its length than across it, so a pad that would be an ordinary conductor with the fibers in-plane becomes a good through-thickness conductor once they are oriented on end. The polymer matrix holds that orientation and supplies the compliance, and contributes little to conduction itself.
That construction is why the numbers on a fiber pad look odd beside a silicone gap pad: a strong through-thickness figure paired with a much weaker in-plane figure. When a supplier quotes a single conductivity, ask which axis it describes.
The ZIITEK TIR®700 series is a concrete data set for the class. Its conductivity figures are flat-plate values under ASTM D5470, the steady-state method used for thin thermally conductive solids, and its hardness figures are durometer readings under ASTM D2240:
| Property | TIR®700 series |
|---|---|
| Through-thickness conductivity | 9–25 W/m·K |
| Thickness | 0.30–5.00 mm overall; the 25 W/m·K grade is offered in a 0.30–0.50 mm band and again from 0.75 mm |
| Hardness | 85 ± 5 OO (0.30–0.50 mm) / 60 ± 10 OO (0.75–5.00 mm) — 25 W/m·K grade |
| Density and specific heat | 2.1–2.9 g/cm³; 0.75–0.93 J/g·°C |
| Service temperature and electrical behavior | −40 to 200 °C; conductive, not an insulator |
| Test methods and compliance | Thickness ASTM D374; hardness ASTM D2240; conductivity ASTM D5470; flame rating V-0 (UL94 equivalent); RoHS and REACH support |
Read the first two rows together and a pattern appears that no table states outright. Within a grade, thickness dominates: the 25 W/m·K material contributes 0.12 °C·cm²/W of bulk resistance at 0.30 mm (0.019 °C·in²/W, the unit the datasheet curves use), 0.30 at 0.75 mm and 2.00 at 5.00 mm. Across grades at the same thickness the ratio is simply the conductivity ratio, so the grade only starts to matter once the thickness is fixed.
Which inverts the usual buying order. The first question is not "which conductivity" but "which thickness does the gap allow" — and the 25 W/m·K list is sparse at exactly the wrong place, jumping from 0.50 mm to 0.75 mm. A gap just above 0.50 mm is therefore filled by the 0.75 mm entry at 20% to 33% compression, well past the 10% to 20% the gap alone would suggest, and the genuinely awkward band is the narrow one around 0.45 to 0.55 mm, where neither entry sits comfortably. The second question is whether the grade is offered at that thickness, and only then does the number on the box decide anything.

Illustration of where the pad sits in a thin stack — a rendering of the arrangement, not a photograph of a specific product.
The Height Budget Comes First, and It Is a Tolerance
A pad is specified at its free thickness and installed at whatever the closed assembly leaves. Compression is (free thickness − installed thickness) ÷ free thickness, and gap pad compression follows a curve, not a single number: it rises as the gap closes, and the force rises with it. Free thickness itself is measured under no load — ASTM D374 is the method on these sheets — which is exactly why the datasheet value tells you nothing about the installed part.
Take a nominal gap of 0.40 mm with ±0.05 mm of stack-up, so the gap runs 0.35 to 0.45 mm. A 0.50 mm pad installs at 30% compression at the tight end and 10% at the loose end. Both ends sit inside the working band that pads in this class are normally specified for, roughly 10% to 40% of free thickness, and the part never bottoms out. A 0.30 mm pad in the same stack is a different story: across the whole range it is thinner than the gap it is meant to fill, so the top of that stack gets air — 0.05 mm at the 0.35 mm end, 0.15 mm at the 0.45 mm end — and a 0.05 mm air layer is a worse conductor than any pad.
Widen the stack to 0.55 mm ±0.05, running 0.50 to 0.60 mm, and the thickness list matters more than the grade. A 0.50 mm pad is exactly the gap at its tight end and thinner than the gap at its loose end, so there is no compression at all. A 0.75 mm pad gives 33.3% at 0.50 mm and 20% at 0.60 mm, both inside the band, and at 0.75 mm the 25 W/m·K grade contributes 0.30 °C·cm²/W.
The awkward case is the one that straddles 0.50 mm: a gap running 0.45 to 0.55 mm. At 0.50 mm the pad gives no compression at the loose end and 10% at the tight one; at 0.75 mm it gives 40% at the tight end, the very top of the band. Neither part is comfortable, and the honest fix is a stack-up change — a boss, a shim, a different shield height — rather than a different grade.
That is the practical cost of choosing by conductivity first: the thickness list is short, and the gap you measured can fall between two entries. The method for turning a measured gap into a specified thickness is worked through in thermal pad thickness for heat sink gaps.
Two numbers belong in the same conversation. Ask for the thickness tolerance as a millimeter figure rather than a percentage band, because ±10% on 0.30 mm is ±0.03 mm and that is the same size as one of the tolerances you are already stacking. And ask what compression set the pad takes after a year at the compression you have chosen: a pad that takes a permanent set stops pressing back, and the contact you designed for at build disappears in the field. How long thermal pads last covers what drives that.
What Pressure Your Assembly Actually Applies
Pressure is force divided by contact area, and in a handheld the force is small. Four newtons is a firm display clip. Spread that over a pad footprint and the resulting pressure is a fraction of what pad datasheets use for their ratings.
| Normal force | Contact area | Pressure |
|---|---|---|
| 2 N | 8 × 8 mm (64 mm²) | 31 kPa (4.5 psi) |
| 3 N | 8 × 8 mm (64 mm²) | 47 kPa (6.8 psi) |
| 5 N | 10 × 10 mm (100 mm²) | 50 kPa (7.3 psi) |
| 8 N | 20 × 20 mm (400 mm²) | 20 kPa (2.9 psi) |
Now compare with the test conditions behind the resistance figures. Pads in this class are commonly quoted at 10 to 20 psi, which is 69 to 138 kPa and above every row in that table; the TIR®700-25 datasheet goes further and plots impedance against pressure from 5 psi, about the middle of the table. Two of the four rows fall below the leftmost point the datasheet plots (5 psi), so no measurement exists for them at all; the other two sit in the lowest fifth of the curve. All four are well under the 10 to 20 psi single-number ratings. The pad is less compressed than it was during the measurement, the real contact area at both faces is smaller, and the number you were quoted is the number you will not get.
A low pressure thermal pad, in this sense, is one whose contact resistance is characterized at pressures a handheld can produce — and the practical test is whether the supplier's curve starts low enough to include your number. "Usable at low pressure" on its own is a weaker claim than it sounds. The thin-band grade at 85 ± 5 Shore OO is not a soft part; it needs force to deflect. If the clip gives 20 kPa, expect less deflection than the flat-platen curve shows, and specify the grade by impedance at your pressure and your installed thickness instead of by the headline figure. The difference between thermal resistance and thermal impedance is the single most useful distinction when two pads are compared on paper.
The Electrical Question You Cannot Skip
TIR®700 is conductive. The datasheet says so plainly: the product is conductive and not an insulating material. In a thin consumer device that is a design constraint with two very different outcomes depending on what the pad touches.
Where both faces sit at the same potential — a die and a shield tied to the same ground — conduction through the pad costs nothing and can help, because the shield becomes part of the heat path. Where the pad could bridge a battery terminal to a chassis, a charging contact to a shield on another rail, or a live trace to a grounded frame, the same property is a short waiting for a tolerance excursion. Thin devices make this likelier rather than less likely: the components are closer together, the shield opening is often only a fraction of a millimeter from a test pad, and a die-cut part that is 0.3 mm oversized reaches things the drawing never showed.
Two rules keep this manageable. Draw the pad outline from the component outline, not from the shield opening, and leave a keep-out ring around anything at a different potential. Then check the potentials explicitly, on the schematic rather than from memory, for every face the pad touches.
If the stack genuinely needs isolation between its two sides, the fiber pad is the wrong part and no amount of die-cut care fixes it. The route is an insulating gap material — ZIITEK's TIS® range runs 1.0 to 1.6 W/m·K with 1500 to 6000 VAC dielectric strength, as described in thermally conductive electrical insulators — and it costs you both conductivity and thickness. That trade is the reason the electrical question belongs at the start of the design, not in a review two weeks before tooling.
Where the Heat Goes: Through-Plane, Not Sideways
Two jobs get confused because both are sold as thermal pads. Crossing one gap is a through-plane job: a hot die, a cold plate above it, and a material in between whose only task is to move heat along the short axis. Spreading a hot spot across a larger area is an in-plane job, and it wants the opposite anisotropy — a graphite sheet, which in ZIITEK's TIR® graphite range reaches 240 to 1700 W/m·K in the X-Y plane against a far lower, grade-dependent figure through it.

The cut edge of a fiber pad: the fibers cross the thickness, which is what makes the part a through-plane conductor. Illustration, not a product photograph.
A carbon fiber pad is a through-plane part. Asking it to spread heat sideways is asking it to work against its own fiber orientation. If the problem in your device is a small die heating a large shield unevenly rather than a die separated from a cold surface, the material is a graphite heat spreader sheet, not a thicker pad. Stacking both is legitimate, but each is then doing its own job, and the pad still has to fit the gap that is left.
Silicone, Optics, and Camera Modules
Read the composition line before repeating the marketing. TIR®700 is carbon fiber in a silicone matrix. A pad with no surface tack and no adhesive layer is not a silicone-free part, and "no stickiness" says nothing about what the matrix does at 85 °C over a thousand hours.
That matters in exactly the places where thin devices put thermal material: beside a lens barrel, under a sensor window, next to an open contact or a MEMS microphone port. Silicone volatiles can condense on an optical surface, and the failure is not gradual — a hazed window on a camera module is a warranty return, not a derating.
The practical move is to ask for data instead of adjectives: outgassing under ASTM E595, reported as total mass loss and collected volatile condensable materials, and any oil-bleed evidence the supplier has. If the answers are thin, the honest alternatives are a non-silicone pad such as Z-Paster®100 at 1.5 to 10 W/m·K, or a low-volatile silicone such as TIF®100L at 1.5 to 6.0 W/m·K. Both give up conductivity against the fiber pad. That is the trade, and it is better made deliberately than discovered in a reliability test. Low-outgassing thermal pads and how to read ASTM E595 data goes through the numbers.
Mass, Stiffness, and What the Clip Feels
Carbon fiber is light for its strength, and that fact gets transferred to pads it has no business being applied to. Run the volume. A 20 × 20 mm pad at 0.30 mm is 0.12 cm³, and the grade offered in that band is the 25 W/m·K one at 2.9 g/cm³: 0.35 g. A 9 W/m·K grade at 2.1 g/cm³ would come out at 0.25 g, but it is not offered at 0.30 mm, so it is not the part in that stack. The same volume in aluminum at 2.70 g/cm³ is 0.32 g — lighter than the pad. Copper at 8.96 g/cm³ is 1.08 g.
So a fiber pad is not a weight saving against an aluminum shim or a stamped shield of the same footprint; it is about 7% heavier, and roughly the same mass in any practical sense. Where the mass argument holds is against copper, and against the general case of replacing a machined metal part with a polymer one. If someone offers light weight as the reason to choose a carbon fiber pad in a thin device, the arithmetic does not support it. The reasons that do hold are compliance at a defined pressure, through-plane conduction, and no adhesive to clean off at rework.
The force side is the more useful calculation. The same 47 kPa over a 20 × 20 mm contact patch is 18.8 N — a great deal to push through a thin plastic boss without bowing the wall behind it. If the structure can only tolerate 5 N at that pressure, the contact area has to come down to about 107 mm² — a shade over 10 × 10 mm, not 20 × 20 mm. Choosing the pad footprint and choosing the load path are the same decision, and the wall thickness usually decides it before the thermal calculation does.
Thermal mass is worth one line for completeness. At 0.35 g and 0.75 J/g·°C the pad holds about 0.26 J/K. A 2 W burst lasting one second would raise it by roughly 8 K if nothing else absorbed the energy. That is not a buffer; do not size a thin-device interface for its transient storage.
Die-Cutting, Placement, and Rework
A fiber pad has no adhesive of its own, which is right for a part that has to be removed and replaced and wrong for a vertical assembly that expects the pad to hold itself. In practice the pad needs a frame, a pocket, or a compression stop that keeps it in place until the stack closes. Designs that rely on the pad staying put by friction alone tend to find it displaced at first article.
The part is also thin enough to be awkward. An ultra-thin thermal pad at 0.30 mm curls, sticks to gloves and picks up dust, so production usually runs kiss-cut parts on a release liner for pick-and-place rather than loose pieces in a bag. The cut edge matters more than it does on a 2 mm pad: a ragged edge sheds fiber and matrix particles, and those particles near an optical surface or an open contact are a defect the thermal test will never catch. Die-cutting for thermal pads and gaskets covers the process side, including what a drawing needs to specify before tooling.
Rework is where the missing adhesive pays you back. There is nothing to scrape, no residue to clean off a shield, and the old part lifts off in one piece — provided the design gave someone a way to reach it.

Kiss-cut fiber pads on liner, the form most thin-device assemblies are placed from.
When Carbon Fiber Is the Wrong Choice
Four situations point away from a fiber pad, and each has a cleaner route:
| Situation | Better route | Why the fiber pad loses |
|---|---|---|
| Gap under about 0.20 mm | Thermal paste or dispensable putty | The pad has almost nothing to compress; two contact resistances dominate |
| Component heights differ by more than the pad can take up | One-component thermal gel | A fixed-thickness sheet cannot follow a stepped profile |
| The two faces are at different potentials | Insulating gap material, or a pad plus an insulating film | The fiber pad conducts, and isolation is not a die-cut problem |
| Heat has to spread sideways | Graphite sheet | In-plane conduction is the wrong axis for a fiber pad |
There is a fifth case that is not about geometry: a stack that is silicone-sensitive and also needs the highest conductivity available. No single material wins that one, and the answer is usually a non-silicone pad at lower W/m·K plus a design change somewhere else. Thermal pad versus thermal paste covers the first row in more depth, including where a paste pumps out and a pad does not.
A Selection Sequence for a Thin Device
Six steps, in this order. Each one can eliminate a candidate before the next is worth doing.
- Measure the installed gap with the stack closed and no pad. Record the minimum and maximum across the tolerance stack, not a nominal. Feeler gauges between the component and the surface above it give this in a few minutes.
- Turn the gap into a free thickness. Pick the thinnest band whose free thickness exceeds the maximum gap, then check that compression at the minimum gap stays under roughly 40%. If no band satisfies both ends, the stack-up is the problem, not the material.
- Calculate the pressure. Total normal force divided by contact area, converted to psi, compared against the pressure at which the impedance figure was measured. If your number is half the test pressure, you are extrapolating.
- Check the potentials. Both faces, from the schematic. If they differ, stop and add isolation before anything else is decided.
- Look at what is next to the pad. Lens, sensor window, open contact, microphone port. If any of them is within a few millimeters, outgassing and oil-bleed data move to the top of the supplier questionnaire.
- Specify from data, not from a headline. Impedance at your pressure and bond line, thickness tolerance measured to a named method, compression set, volume resistivity, outgassing numbers, and die-cut capability including edge quality. Compliance paperwork — RoHS, REACH, and the UL 94 rating of the grade if the end product has a flammability requirement — is a document request, and a supplier who cannot answer it is telling you something.
That list is also the specification sheet to send a supplier, and it is a fair test of whether the supplier has the data at all. The device-level view behind it, across pads, gels, graphite and insulators, sits in the consumer electronics thermal pad selection hub; the M.2 case in thermal pads for SSD and M.2 is the same arithmetic in a different housing.
If you have a stack drawing, the useful next step is not a catalogue: send the gap range, the clip force and the potentials on each face, and the thickness band follows from the answers. ZIITEK's thermal engineering team works from those three inputs when a thin-device interface is being specified, and the TIR®700 carbon fiber thermal pad grade is one option among several rather than the default.